Skip to main content

LifeBox – Design of an organ transport container for extending preservation times for transplant, specifically adapted for drone flight


Title: LifeBox – Design of an organ transport container for extending preservation times for transplant, specifically adapted for drone flight.
(https://timesofindia.indiatimes.com/home/science/iisc-lifebox-to-aid-organ-transfer-by-drones/articleshow/64450470.cms)
  
Lab/Affiliation: CPDM, Indian Institute of Science, Bangalore 

Salary: As per IISc. norms (22-24k PM for Project Assistant;  30-33k PM for Project Associate)


Essential Qualifications: B.Tech/M.Tech in ECE/EEE/Instrumentation with sound knowledge in Embedded Systems, Circuit Design, Control System Design, Board Bring-up

Desirable Skills: Knowledge about quality systems for medical devices and EMC standards, good documentation skills, must be a team player (the nature of work
demands coordination with several people involved in the project).

Task:

The selected staff is expected to

1.  Integrate multiple sensors and actuators with microcontrollers

2.  Design and test a control system using sensor feedback

3.  Develop a graphical user interface for the system

4.  Design and develop a PCB enclosing all electronic components involved 

Commitment Required: 6 months – 1 year, starting as soon as possible. 

Interested candidates satisfying the above requirement can email their resume to Prof. B. Gurumoorthy (bgm@iisc.ac.in ), Prof. Ashitava Ghoshal
(asitava@iisc.ac.in) with a CC to devalkaria@iisc.ac.in

Comments

Popular posts from this blog

Statistics in Flow Cytometry Data and "MFI" values

                                 The speed of the flow cytometry offers wide range of data points and data plots. Due to its sensitivity and versatility, it has been used extensively. Flow cytometer can detect up to 1000s of cells per second.. But, it should be noted that the flow cytometry also involves the statistics, its significance, calculating the fluorescence intensity..                Statistics in flow cytometry involves, total number of data points acquired, percentage population, most importantly mean and median fluorescence intensity, and others. Most of us get confused about the term "MFI", whether it means mean fluorescence intensity or median fluorescence intensity.. Truth is, both.. It means it can be described as either mean or median fluorescence intensity. Some researchers use Mean for MFI and some use Median for MFI values.  (Keep...

Fluorescence Spectrum Viewers Tool.

                Spectra Viewers are the fluorochrome tools which help in understanding the wavelength ranges of excitation and emission of fluorochromes.. These tools are very helpful in determining specific laser, detectors and range of fluorescence spectra. When Multi-Color Flow Cytometry is the experiment, then these must be used to analyze emission spectrum, fluorescence spill over and compensation values. How these tools help.. First, Lets consider a simple example of analyzing the spectrum for Green Fluorescence Protein (GFP) and you want to know the excitation wavelength and emission wavelength range for GFP. By knowledge, you know that GFP will excite with 488nm Blue laser and emits the green fluorescence at apporximately 510nm.. Now, just open a spectrum viewer and select the GFP as shown below. Now, you have analyzed GFP fluorescence and received the knowledge that It excites with 488nm Blue Laser and emission maximum is...

Compensation in Flow Cytometry (Fluorescence Spill Over Correction).

                      The term "Compensation" in flow cytometers refers to the process of correcting fluorescence spill over. The compensation matrix ensures that the fluorescence emitted is detected in a particular detector which is from the fluorescence being measured. As we all know that most of the fluorescence molecules have broad emission range. if more than one one fluorescence is selected, their emission spectra may overlap. To correct this spectral overlap in cytometry data, a mathematical matrix called compensation is used. The Intention of this article is to teach you the compensation from basic theory to practical. This example for FITC and PE fluorescence molecules shows that, Some of the FITC fluorescence is being detected in PE Detector. and Some of the PE fluorescence is being detected in FITC Detectors. Task here is to make sure that in cytometry data, FITC is in FITC detector only and PE is in PE Detector only....